• 設計及び問い扱い説明書
  • ユニバーサルジョイントの選定手順
  • ご注文に際してのお願い

Adjuster for MARU-pipe

for measurement, experiment or jigadjustment

material : duralumin (A2017)

cad
*For small diameter pipe, please insert L-length type into big diameter pipe and tighten.
MARU-pipe dimension list
Part No.  H8
φd1
 H8
φd2
φD L W Cap screw Horizontal load N
RAJ-0608 6 8 17 30 11 2-M3 86
RAJ-0810 8 10 19 40 13 113
RAJ-1013 10 13 23 50 16 2-M5 235
RAJ-1216 12 16 28 60 19 2-M5 544
RAJ-1619 16 19.05 33 70 24 735
RAJ-2025 20 25.05 42 80 32 936
*Please select any pipe of same O.D with the bore φd1,φd2.
We can be of assistance in terms of wall thickness.
※You may download 3D CAD drawings by clicking on the part number of interest.